Comparison of the dialysis efficacy between two reinfusion control systems in online haemodiafiltration

The dose of dialysis and the volume of reinfusión are key elements in the best results communicated in the hemodiafiltration online. Technological advances allow two forms of automated control of reinfusion volume (a volume-based and a pressure-based control system), and two methods of measuring Kt obtained by ionic dialysance (OCM and Diascan). The purpose of this study was to compare both these control systems. We designed a prospective, crossover study of the prevalent population in post-dilution on-line hemodiafiltration, with explicit consent. For 2 consecutive weeks, three sessions were performed with automatic reinfusion according to hematocrit and total protein values and Kt measurement with OCM, and three sessions were performed with automatic reinfusion according to transmembrane pressure and Kt measurement with Diascan. The average reinfusion volume and Kt were compared. Variables were contrasted with Student's t-test for related samples. Statistical significance was set at p <0.05. Sixteen patients concluded the study (56% men, with a mean age of 58.8 years). A total of 81.3% had autologous or prosthetic fistulas for vascular access. Reinfusion volume was significantly higher (p = 0.029) under pressure control (23.24 ± 2.55 lversus 21.81 ± 1.75 l) while Kt measured by OCM was significantly (p <0.001) higher than that measured by Diascan (59.94 ± 5.05 l versus 55.12 ± 4.15 l. We found a 6.2% increase in volume reinfusion under pressure control, although both methods performed well in the final convective transport liters. The dialysis dose (Kt) was higher when OCM was used.

Mentions
Figures
Figure 1 Figure 2
Altmetric
References
  1. Maduell F y Arias M. Indicaciones y prescripción de la hemodiafiltración. Dial Trasp 2008: 29(2) , 62-66 .
  2. Maduell F, García H, Hernández-Jara J y cols. Comparación de la infusión predilucional versus postdilucional en la hemodiafiltración en línea. Nefrología 18; Supl , 3-49 (1998) .
  3. Maduell F. Convección versus difusión. ¿Ha llegado el momento del cambio? Nefrología 29(6) , 589-593 (2009) .
  4. Alfaro A, Gallego B y cols. HDF en línea en nuestros pacientes: calidad de vida y capacidad funcional. Premio Fresenius Medical Care hemodiafiltración on-line. Rev Soc Esp Enferm Nefrol 9 (3) , 158-163 (2006) .
  5. Canaud B, Braga-Gresham JL, Marshal MR y cols. Mortality risk for patients receiving haemodiafiltration versus haemodialysis: European results from the DOPPS. Kidney Int. 69 , 2087-2093 (2006) .
  6. Jirka T, Cesare S, Di Benedetto y cols. Mortality risk for patients receiving hemodiafiltration versus hemodialysis. Kidney Int 2006, 70 , (1524) .
  7. Fernández AV, Soto S, Arenas M, y cols. Comparación de infusion automatica respecto a manual en hemodiafiltración on line posdilucional. Premio Fresenius Medical Care. Rev Soc Esp Enferm Nefrol13(1) , 17-22 (2010) .
  8. Joyeux V, Sijpkens Y, Haddj-Elmrabet A y cols. Optimized convective transport with automated pressure control in on-line postdilution hemodiafiltration. Int J Artific Organs31(11) , 928-936 (2008) .
  9. Held PJ, Port FK, Wolfe RA, y cols: The dose of hemodialysis and patients mortality. Kidney Int50 , 550-556 (1996) .
  10. Vanesa AV, Soto S, Arenas M, y cols. Estudio comparative de la dosis de diálisis medida pot Kt y Kt/V. Rev Soc Esp Enferm Nefrol12(2) , 97-102 (2009) .
  11. Kulhmann U, Goldau R, Samadi N y cols. Accuracy and safety of online clearance monitoring based on conductivity variation. Nephrol Dial Transplant16 , 1053-1058 (2001) .
  12. Maduell F, Vera M, Arias M, y cols. Influence of the ionic dialysance monitor on Kt measurement in hemodialysis. Am J Kidney Dis52(1) , 85-92 (2008) .
  13. Teatini U, Stechiph D, Romei G. Evaluation of a new online haemodiafiltration mode with automates pressure control of convection. Blood Purif 2011:31 , 259-267 .
  14. Frouget T, Joyeux V, Haddj-Elmrabet A, y cols: Hémodiafiltration en 2005: faut-il continuer à prescrire un volume à infuser ou opter pour la prescription d'une pression transmembranaire constante?. Réunion commune Société francophone de dialyse et Société de néphrologie, Clermont-Ferrand, Septembre(abstract 31) , (2005) .
Expand